[Dec-2021] Updated Cisco Channel Partner Data Center 500-920 Exam Questions BUNDLE PACK Master The Cisco Content 500-920 EXAM DUMPS WITH GUARANTEED SUCCESS! Cisco 500-920 Exam Syllabus Topics: TopicDetailsTopic 1Troubleshoot FEXTopic 2Troubleshoot data center unified computingTopic 3Troubleshoot storage area networks, including Fibre Channel, FCoE, zoning, NPV, and NPIVTopic 4Troubleshoot virtualization [...]

[Dec-2021] Updated Cisco Channel Partner Data Center 500-920 Exam Questions BUNDLE PACK [Q13-Q29]

Share

[Dec-2021] Updated Cisco Channel Partner Data Center 500-920 Exam Questions BUNDLE PACK

Master The Cisco Content 500-920 EXAM DUMPS WITH GUARANTEED SUCCESS!


Cisco 500-920 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Troubleshoot FEX
Topic 2
  • Troubleshoot data center unified computing
Topic 3
  • Troubleshoot storage area networks, including Fibre Channel, FCoE, zoning, NPV, and NPIV
Topic 4
  • Troubleshoot virtualization solutions

 

NEW QUESTION 13
Which statement regarding the UCS C-senes connectivity modes best describes connectivity options in a UCS Manager integrated environment?

  • A. UCS C-series servers may be connected with or without the use of Fabric Extenders (FEX) in environments running UCS Manager Software Release 2 2 or later
  • B. All UCS C-series servers in a single UCS Manager domain must share the same connectivity model
  • C. UCS C-series servers may be connected to multiple UCS Manager domains at the same time
  • D. UCS C-series servers must be connected to Fabric Interconnects using Fabric Extenders (FEX)

Answer: A

 

NEW QUESTION 14
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?

  • A. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
  • B. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects
  • C. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
  • D. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
  • E. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects

Answer: A

 

NEW QUESTION 15
When server is booting from SAN, which command verifies the PLOGI sessions with the target?

  • A. FCIist
  • B. Lunlist
  • C. FCMap
  • D. Lunmap

Answer: B

 

NEW QUESTION 16
Which Cisco UCS internal component maintains the UCS XML database, manages the FSM stages and operations and instructs the Application Gateway to perform operations on physical and logical elements?

  • A. Cisco Application Gateways
  • B. Cisco Data Management Engine
  • C. Cisco Finite State Machine
  • D. Cisco UCS Manager

Answer: B

Explanation:
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/System-Monitoring/3-1/b_UCSM_GUI_System_Monitoring_Guide_3_1/b_UCSM_GUI_System_Monitoring_Guide_3_1_chapter_0100.html

 

NEW QUESTION 17
The UCS Chassis Discovery Policy has been set to four and a new chassis is connected with two links What is the resulting chassis recognition action?

  • A. The chassis will not be recognized
  • B. The Chassis Discovery Policy will automatically reset to two links, since it always tracks the physical connections
  • C. The chassis will be recognized and both links will be active
  • D. The chassis will be recognized but only one of the links will be active.

Answer: A

 

NEW QUESTION 18
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?

  • A. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
  • B. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
  • C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
  • D. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.

Answer: C

 

NEW QUESTION 19
What occurs that causes a Split Brain Issue with Fabric Interconnects?

  • A. Manage configuration changes made with UCS Manager
  • B. The subordinate Fabric Interconnect detects heartbeat failure and declares itself primary
  • C. Both cluster links fail
  • D. A quorum tie occurs that must be resolved by the SEEPROM

Answer: B

 

NEW QUESTION 20
In Cisco UCS, there are several interfaces involved on the packet path from the vNIC through the adapter, IOM to finally reach Pi Which is the order of those interfaces, starting from the vNIC?

  • A. HIF. SIF, VIF, UIF NIF
  • B. VIF, UIF, HIF, NIF SIF
  • C. HIF. NIF, UIF, VIF SIF
  • D. VIF, UIF, HIF, SIR NIF

Answer: D

 

NEW QUESTION 21
When troubleshooting a LAN connectivity issue, you notice a failed uplink from the Cisco UCS Fabric Interconnects to the upstream LAN switch. What two could be causing the issue? (Choose two )

  • A. A port channel mismatch between the Fabric Interconnects and the upstream LAN switch
  • B. Misconfigured QoS parameters on the failed uplink
  • C. Misconfigured VLAN on the failed uplink
  • D. A port speed configuration mismatch between the Fabric Interconnects and the upstream LAN switch
  • E. A SFP Type mismatch between the Fabric Interconnects and the upstream LAN switch

Answer: A,B

 

NEW QUESTION 22
Which ethernet port type is used when configuring UCS Fabric Interconnect connections to Cisco UCS C-series servers?

  • A. Server Port
  • B. Uplink Port
  • C. Direct Connect Port
  • D. Service Profile Port

Answer: B

 

NEW QUESTION 23
A new UCS dual fabric cluster is being configured with a single chassis. The administrator notices that the cluster is not in High Availability (HA) mode. What is the possible cause?

  • A. The HA plugin has not been installed in UCS Manager
  • B. The links to the chassis are not enabled
  • C. The UCS-FI-HA license has not been activated in UCS Manager
  • D. No uplinks are active into the data center.

Answer: A

 

NEW QUESTION 24
In a Cisco UCS Manager, if all KVM sessions to each server fail to start, what is likely causing the problem?

  • A. The workstation you are using to connect to the KVM session is the problem
  • B. The Fabric Interconnect to which you are connected has a problem
  • C. The I/O Modules in the chassis are the problem
  • D. Cisco UCS Manager has a problem

Answer: A

 

NEW QUESTION 25
When troubleshooting, which option is the primary uses of the SCOPE command?

  • A. The SCOPE command is not helpful in this case
  • B. To access the log files on the virtual machines
  • C. To access the log files that reside in a component
  • D. To access the log files on the log server

Answer: C

 

NEW QUESTION 26
Which two ports on a pair of Cisco Fabric Interconnects must be properly cabled for the pair to form a cluster? (Choose two )

  • A. L2 > L1
  • B. L1 > L2
  • C. L1 > L1
  • D. L2 > L2

Answer: C,D

 

NEW QUESTION 27
In order to create an Inband Profile for Cisco Integrated Management Controller (IMC) connectivity, what do you need to perform first?

  • A. Create different VLANs, with different VLAN IDs
  • B. Create a Management IP Pool, a VLAN. and a VLAN Group
  • C. Create a Management IP Pool, a MAC Address Pool, and a VLAN Pool
  • D. Create a Service Profile
  • E. Create an IPMI Policy

Answer: D

 

NEW QUESTION 28
When troubleshooting UCS initialization issues that require Fabric Interconnect reboots, which Fabric Interconnect should be rebooted first?

  • A. The Cisco UCS Manager will determine with Fabric Interconnect to reboot
  • B. The primary Fabric Interconnect
  • C. The subordinate Fabric Interconnect
  • D. Both Fabric Interconnects must be rebooted simultaneously

Answer: B

 

NEW QUESTION 29
......

Pass Cisco 500-920 Exam – Experts Are Here To Help You: https://torrentvce.exam4free.com/500-920-valid-dumps.html